Issue: Volume 24 - Number 1
Publishing Date: março 2019
Editor-in-Chief: Marcello Mezaroba
Editor Affiliation: Universidade do Estado de Santa Catarina
Implementação de funcionalidade de amortecimento de propagação harmônica em equipamento de armazenamento e suporte de rede
Wilson Sant’Ana, Robson Bauwlez Gonzatti, Germano Lambert-Torres, Erik Leandro Bonaldi, Rondineli Rodrigues Pereira, Luiz Eduardo Borges da Silva, Guilherme Gonçalves Pinheiro, Carlos Henrique da Silva, Denis Mollica, Joselino Santana filho
27-36
http://dx.doi.org/10.18618/REP.2019.1.0018
Portuguese Data

Palavras Chaves: Amortecimento de Ressonâncias, Conversores multiníveis, Filtros Ativos, Resistência Harmônica

Resumo

Este trabalho trata do amortecimento de propagação harmônica em linhas de distribuição, visando melhora na qualidade da tensão. A propagação harmônica ocorre devido às ressonâncias entre as impedâncias indutivas do sistema e bancos de capacitores utilizados em filtros passivos e compensadores de reativos, amplificando a distorção causada por cargas não lineares nas proximidades, e pode ser amortecida através do uso de filtros ativos emulando resistências harmônicas. Esta abordagem (ao invés do uso convencional dos filtros ativos shunt para diretamente compensar as correntes harmônicas) é muito atrativa para sistemas de distribuição, aonde as cargas não lineares estão distribuídas e inacessíveis.
A contribuição principal deste artigo é a implementação desta resistência harmônica em um equipamento de armazenamento de energia e suporte de rede como uma funcionalidade extra, sem necessidade de sensores adicionais.
Resultados experimentais são apresentados em uma bancada de testes.

English Data

Title: Implementation of harmonic propagation damping feature on a storage and grid support equipment

Keywords: Active Power Filters, Harmonic Resistance, Multilevel converters, Resonance Damping

Abstract

This work discusses harmonic propagation damping on distribution lines, aiming for better voltage quality. The harmonic propagation is due to resonances between the inductive impedances of the system and the capacitor banks installed in passive filters and reactive power compensators, amplifying the distortion caused by non-linear loads nearby, and can be damped with the use of active filters emulating harmonic resistances. This approach (instead of the conventional use of shunt active filters to directly compensate harmonic currents) is very attractive for distribution systems, where the non-linear loads are distributed and inaccessible.
The main contribution of this paper is the implementation of this harmonic resistance in an energy storage and grid support equipment as an extra feature, without the need of additional sensors.
Experimental results are presented in a test bench.

References

[1] B. Singh, K. Al-Haddad, A. Chandra, A review of active filters for power quality improvement, IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 960-971, Oct. 1999, https://doi.org/10.1109/41.793345.
[2] L. B. G. Campanhol, S. A. O. da Silva, A. Goedtel, Filtro ativo de potência paralelo aplicado em sistemas trifásicos a quatro-fios, Eletronica de Potencia, vol. 18, no. 1, pp. 782-792, fev 2013, http://dx.doi.org/10.18618/REP.2013.1.782792.
[3] J. R. de Souza Martins, D. A. Fernandes, F. F. Costa, M. B. de Rossiter Correa, Compensação de tensão trifásica em cargas sensíveis baseada em um sistema de controle repetitivo e mínimos quadrados, Eletronica de Potencia, vol. 22, no. 3, pp. 237-245, set 2017, http://dx.doi.org/10.18618/REP.2017.3.2681.
[4] F. Z. Peng, Application issues of active power filters, IEEE Industry Applications Magazine, vol. 4, no. 5, pp. 21-30, Sep./Oct. 1998, https://doi.org/10.1109/2943.715502.
[5] H. K. M. Paredes, P. H. F. dos Reis, S. M. Deckmann, Caracterização de cargas lineares e não lineares em condições de tensões não senoidais, Eletronica de Potencia, vol. 22, no. 1, pp. 50-62, mar 2017, http://dx.doi.org/10.18618/REP.2017.1.2647.
[6] H. Akagi, New trends in active filters for power conditioning, IEEE Transactions on Industry Applications, vol. 32, no. 6, pp. 1312-1322, Nov./Dec. 1996, https://doi.org/10.1109/28.556633.
[7] X. Sun, J. Zeng, Z. Chen, Site Selection Strategy of Single-Frequency Tuned R-APF for Background Harmonic Voltage Damping in Power Systems, IEEE Transactions on Power Electronics, vol. 28, no. 1, pp. 135-143, Jan 2013, https://doi.org/10.1109/TPEL.2011.2179121.
[8] X. Sun, R. Han, H. Shen, B. Wang, Z. Lu, Z. Chen, A Double-Resistive Active Power filter System to Attenuate Harmonic Voltages of a Radial Power Distribution Feeder, IEEE Transactions on Power Electronics, vol. 31, no. 9, pp. 6203-6216, Sept 2016, https://doi.org/10.1109/TPEL.2015.2500913.
[9] H. Bai, X. Wang, F. Blaabjerg, A Grid-Voltage-Sensorless Resistive-Active Power filter With Series LC-filter, IEEE Transactions on Power Electronics, vol. 33, no. 5, pp. 4429-4440, May 2018, https://doi.org/10.1109/TPEL.2017.2717183.
[10] T.-N. Le, M. Pereira, K. Renz, G. Vaupel, Active damping of resonances in power systems, IEEE Transactions on Power Delivery, vol. 9, no. 2, pp. 1001-1008, Apr. 1994, https://doi.org/10.1109/61.296284.
[11] K. Wada, H. Fujita, H. Akagi, Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder, IEEE Transactions on Industry Applications, vol. 38, no. 4, pp. 1123-1130, Jul./Aug. 2002, https://doi.org/10.1109/TIA.2002.800584.
[12] W. C. Santana, K. Al-Haddad, L. E. B. da Silva, Modeling and Active Damping of Harmonic Propagation on Electric Distribution Systems, in
Proceedings of the IEEE Electrical Power and Energy Conference EPEC’09, Montreal, Canada, Oct. 2009, https://doi.org/10.1109/EPEC.2009.5420880.
[13] P. Jintakosonwit, H. Akagi, H. Fujita, S. Ogasawara, Implementation and performance of automatic gain adjustment in a shunt-active filter for harmonic damping throughout a power distribution system, IEEE Transactions on Power Electronics, vol. 17, no. 3, pp. 438-447, May 2002, https://doi.org/10.1109/TPEL.2002.1004252.
[14] T. L. Lee, S. H. Hu, Discrete Frequency-Tuning Active filter to Suppress Harmonic Resonances of Closed-Loop Distribution Power Systems, IEEE Transactions on Power Electronics, vol. 26, no. 1, pp. 137-148, Jan 2011, https://doi.org/10.1109/TPEL.2010.2052833.
[15] P. Tenti, T. Caldognetto, S. Buso, D. I. Brandao, Control of utility interfaces in low-voltage microgrids, Eletronica de Potencia, vol. 20, no. 4, pp. 373-382, nov 2015, http://dx.doi.org/10.18618/REP.2015.4.2556.
[16] N. Pogaku, T. C. Green, Harmonic mitigation throughout a distribution system: a distributed-generator-based solution, IEE Proceedings – Generation, Transmission and Distribution, vol.153, no. 3, pp. 350-358, May 2006, https://doi.org/10.1049/ip-gtd:20050086.
[17] W. Sant’Ana, R. Gonzatti, G. Lambert-Torres, E. Bonaldi, R. Pereira, L. E. B. da Silva, C. H. Silva, G. Pinheiro, D. Mollica, J. S. filho, Suporte e formação de micro-redes através de conversor multinível, in Anais do XXII Congresso Brasileiro de Automática – CBA2018, Joao Pessoa-PB, Brazil, Set 2018.
[18] W. Sant’Ana, R. Gonzatti, B. Guimaraes, G. Lambert-Torres, E. Bonaldi, R. Pereira, L. E. B. da Silva, C. Ferreira, L. de Oliveira, G. Pinheiro, C. H. da Silva, C. Salomon, D. Mollica, J. S. filho, Development of a multilevel converter for power systems applications based on DSP, in anais do VII Simpósio Brasileiro de Sistemas Elétricos (SBSE), Niteroi-RJ, Brazil, maio 2018, https://doi.org/10.1109/SBSE.2018.8395608.
[19] L. Asiminoaei, F. Blaabjerg, S. Hansen, Detection is key – Harmonic detection methods for active power filter applications, IEEE Industry Applications Magazine, vol. 13, no. 4, pp. 22-33, Jul./Aug. 2007,
https://doi.org/10.1109/MIA.2007.4283506.
[20] M. J. Newman, D. N. Zmood, D. G. Holmes, Stationary frame harmonic reference generation for active filter systems, IEEE Transactions on Industry Applications, vol. 38, no. 6, pp. 1591-1599, Nov 2002, https://doi.org/10.1109/TIA.2002.804739.
[21] C. L. Phillips, H. T. Nagle, Digital Control Systems Analysis and Design, 3rd ed., Prentice Hall, Inc., Upper Saddle River, New Jersey, 1995.
[22] R. B. Gonzatti, S. C. Ferreira, C. H. da Silva, L. E. B. da Silva, G. Lambert-Torres, L. G. F. Silva, Hybrid active power filter applied to harmonic compensation of current-source type and voltage-source type nonlinear loads, in 2013 Brazilian Power Electronics Conference, pp. 1257-1262, Oct. 2013, https://doi.org/10.1109/COBEP.2013.6785277.
[23] S. A. O. da Silva, L. B. G. Campanhol, V. D. Bacon, L. P. Sampaio, Single-phase grid-connected photovoltaic system with active power line conditioning, Eletronica de Potencia, vol. 20, no. 1, pp. 8-18, fev 2015, http://dx.doi.org/10.18618/REP.2015.1.008018.
[24] C. X. Rocha, J. R. Camacho, E. A. A. Coelho, W. A. Parreira, Selective three-phase current reference generation using multi-resonant method for shunt active power filter, Eletronica de Potencia, vol. 22, no. 1, pp. 19-30, mar 2017, http://dx.doi.org/10.18618/REP.2017.1.2642.
[25] “IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems”, IEEE Std 519-2014 (Revision of IEEE Std 519-1992), pp. 1-29, June 2014, https://doi.org/10.1109/IEEESTD.2014.6826459.
[26] ANEEL – Agência Nacional de Energia Elétrica, “PRODIST – Módulo 8 – Qualidade de Energia Elétrica”, revisão 10, 2018.

Seja um
Associado

A afiliação à SOBRAEP permite aos sócios (Efetivos, Aspirantes e Corporativos) acesso completo ao site da SOBRAEP e descontos em inscrições de alguns congressos da área, além da participação nos Webinars promovidos pela associação. Também existem três tipos de patrocínio disponíveis para o site/COBEP.